Six Largest Mistakes Made when Hiring a Cabling Contractor
Data cabling and voice recognition systems is often ignored by many companies in the last minute, just before the relocation or new construction takes place. Many information professionals consider a low priority or something that takes a few steps from their budget for the actual network components such as servers or software. However, the management of a state of art wiring system is equally important that good reliable server in a network. Wiring is the backbone of any computer network linking all parts of the network must be given as much care as a component of the network.
Number one mistake – Blindly choosing the lowest bidder
It is the most common mistake made during installation of voice and data network cabling. Often the lowest bid to the contractor, which is the smallest, the least experience of one or a mistake on their offer. Before the implementation of this decision you need to know your contractor. Find out how long they been in business, visit major facilities and have to go by all means visit their offices and warehouse. A site visit to their office will tell you the most, what you need to know about an organization. Make sure your contract and size of similar scope is completed.
Error number two – the selection of product manufactured, installed
Many companies have tried to standardize on a specific brand of cable systems. Some of the largest manufacturers Belden, Comscope, Ortronics, AMP and Leviton. You can not go wrong with one of those big names. However, in order to standardize the managers and executives trying to get up, because it makes things easier for IT staff think hung. The reality of the situation is that if you’re one of the biggest names are the only elements that may not be interchangeable facades to be elected. Of course there are performance criteria as well, and they all claim to be the best. Do your own research and choose a finished product, you feel a strong company that will get behind their product if you had to make a claim
Error number three – pay too much for the latest cabling technologies
The fact is that today’s network devices and network components of the future can not have the specifications for Cat 5e and Cat 6 cabling components. Combine this with the fact that the average company moves every 3-4 years. You will find it difficult to meet the future security of a building does not qualify. Do you watch the current infrastructure, the equipment you plan to do or requests to add or update? Is Gigabit or 10 Gigabit Ethernet option for you in the near future?
Error number four – not with universal wiring
The EIA / TIA and BICSI recommend both a universal platform for wiring your communication infrastructure. installed in the days to the average would be one voice quality cable for the phone system and a single data cable quality (Cat 3, CAT5, CAT5e or Cat 6) are made for their computers. This is of course dedicated to ease of use of these cables to a type of system. This will be exacerbated by the termination procedure. Voice cables are traditional 66-style blocks (finished 50-66m1) which are not easy to use and requires a special tool and the interconnecting cables to make changes. phone companies have a year killing only perform MAC work (moves, adds and changes) because a customer was unable or unwilling to confront the phone closet and lead the MAC I work.
The practice of using a universal platform for real-wiring is now the standard for all wiring reputable contractors. A platform of universal cabling includes all data from high quality components that are compatible for all voice applications. A common system would be completed by 3 Category 5e or 6 cables of all kinds on a patch panel 110. end wall plate all the proper cables to Grade 8 position modular jack is (wrongly that knowledge an RJ-45). This design not only allows for maximum flexibility, customers could have three computers and three telephones and two computers and a phone or configuration that worked for their application. The fact is that the client has complete control of their cabling infrastructure now and does not need to pay a contractor to come in whenever they move into an office. Finally, it will also save you money throughout the wiring system as it is moved and Flex to make your requirements, without wiring to meet your party are. Remember that the contractor has been completed in accordance with the construction, it aims to remove the ceiling tiles and standing on the desk while you try to make money. The elimination of the disease itself, it is worth it.
Error number five – CAD no pre-installation and post installation CAD drawings.
Most customers really have no idea what their platform will look at the wiring of their registration documents to the research. They rely on their contractor to do the right thing. “Do not make this mistake if you do not understand how your infrastructure looking for work or what should not be signed. Your contractor should be able to take your construction plans and summary of your wiring diagram on its plans. This gives you a visual representation of what you pay and you can ask questions. Similarly, if the order is complete, you should receive a so- saying “as-built drawing” shows based on your point of communication with a number of standards. Some contractors will even show the scale of the investigation, did you patch panels are and how much space you have in each rack and left for growth or other devices. This should be made available both on paper and in AutoCAD format for your architect to build your final view on how to build.
Error number six – not always a design before the work begins.
This seems to be everywhere in the council, some people have no plan design what so ever. Some pay $ 10,000 for an engineering firm to examine a specification that they were free to book for the spec. Let us not deceive you, this is a great spec spec good. Often, a specification with the time period for submission of the contractor and to prevent unnecessary amounts of homes, as presented by the right contractor bidding on your project. What you want is a specification that clearly defined, realistic to your needs, basic skills in points and do it as fast and as simple as possible. Do not try to write a spec that cover all eventualities, you out of your contract and you do not confuse the process. Once you have your party on an apple comparison based Apple s selected, you can always and should always sit down to discuss the project and other options they recommend. One last thing, always, always the entrepreneur will provide a quantitative estimate, and not individual prices, only quantities. This will help you begin to eliminate contractors who have done their homework, if you compare to its list of parts.
Error number six – no cable management
All wiring will be held prior to use, the look is simple. Show me the wiring system after six months, and I tell you when the good management of wire was used. “Used” is the keyword here. Remember, you can have the best cable management in the world if you do not strictly enforce its use with your personal computer, you have chaos. In other words, the contractor must provide you with a good design. My advice is, listen to your contractor, they know more than you about them. Then go visit sites that suggest how they are made. See how they look, after using a couple of months. Ask them to keep the customer how easy it is organized. Do not underestimate the value of this step. If your patch panels are a mess, and you can not control changes in a timely and orderly, your contractor paid more for work MAC would do for you.